Cryogenics is used to liquefy gases such as oxygen, hydrogen, helium, argon and nitrogen at temperatures between -150°C and absolute zero (-273°C).

Cryogenic tanks are manufactured to transport and store liquid phase nitrogen (LIN), liquefied argon (LAR), liquefied oxygen (LOX). LOX tanks are specially designed and manufactured according to 2014/68/EU Pressure Equipment Directive (PED) EN13445-Annex C for long-term storage of cryogenic liquefied gases under pressure.

Get Offer
Cryogenic tanks
Max Allowable Operation 19 Bar
Design Temperature -196 C
Project Category Stainless Steel (1100028-3) according to EN-10028-7
 Insulation  Perlite and Vacuum
  • Optional long-distance control with telemetry
  • TUV Austria Approved and CE Certified
  • Standard manual or optional digital level display
  • Ease of use with control panel
Model Number Gross Capacity Net Capacity (95% Occupancy Rate) Daily Evaporation %/Day ∅D (mm) B (mm) L (mm) W (mm) H (mm) Empty Weight
(kg)
GZ90.05 6200 5890 0,30 1830 5120 5910 2050 2120 3750
GZ90.10 10450 9930 0,29 2400 4640 5340 2400 2690 5300
GZ90.15 14850 14110 0,28 2400 6130 6830 2400 2690 6950
GZ90.25 24750 23510 0,24 2400 9925 10625 2400 2690 10800
GZ90.30 31300 29735 0,23 2680 9600 10300 2680 3020 11750
GZ90.50 50000 47500 0,19 3050 9600 11300 10050 12000 20500
  • Designed and manufactured according to PED 97/23/EC.
  • CE marked
  • Maximum permissible operating pressure is 40 bar.
  • Cleaned for oxygen service.
  • It has an efficient fin tube design.
  • Optimized external and internal surfaces for optimum benefit
capacity Outer Surface Capacity For Lox (Nm3 / Hour)
GZ90.05 29 93
GZ90.10 59 186
GZ90.15 117 372
GZ90.25 205 560
GZ90.30 292 929
GZ90.50 400 1274


Ambient Air Vaporizer

Ambient air vaporizers do not require an external source during operation. It provides vaporization through heat exchange with the surrounding air.

The liquefied gas is vaporized and heated to ambient temperature. It is made available to the end user as gas. According to the type of vaporizer, it can be used with a Fin tube or fan assisted.


You can choose evaporators produced in various capacities by considering the following notes:

  • Evaporator selection is made according to hospital consumption.
  • The evaporator must change between reserves every 8 hours.
  • Evaporator capacity should be selected according to temperature, working time and liquid type. The evaporator outer surface should be selected according to the conditions of the site.